Tankvision
Inventory management
Gauge Link NXA20

Tankvision NXA20 ©Endress+Hauser

Acquires data from non Endress+Hauser field instruments and converts it to Modbus

Gauge Link NXA20 scans parameters from tank gauges with TRL/2 protocol from Emerson Rosemount or BPM protocol from Honeywell Enraf and converts the signal to Modbus RS485 as one part of Tankvision, which is a dedicated tank inventory system. For a step-by-step site upgrade, the Tankvision Gauge Link together with the Tankvision Tank Scanner allows legacy protocol management as well as gradual upgrades for more flexibility. It is ideally suited for small depots as well as bigger tank farms.

  • Преимущества

    • Legacy protocol management

    • Step-by-step site upgrade

    • Higher system availability

  • Область применения

    Scans parameters from tank gauges. Suited for tank farms with various protocols used for communicating with the installed field devices.

    • Provides data to the Tank Scanner NXA820 via Modbus

    • Ambient temperature: -40 to +60°C (-40 to +140°F)

Характеристики и спецификации

Назад

Details

  • Принцип измерения

    Протокол передачи данных

  • Функция

    Привязка датчика

    Преобразователь протоколов

    Получение данных от полевых приборов с помощью протоколов Enraf BPM или Saab TRL/2 и преобразование данных в Modbus RS-485.

  • Вход

    Enraf BPM; Saab TRL/2

  • Выход

    Modbus RS485

  • Питание

    Пер. ток: 90...250 В перем. тока

  • Размеры (ШxВxГ)

    91 x 104 x 140 мм (3,6 x 4,1 x 5,5 дюйма)

  • Конфигурация

    Через последовательный порт

Документы / руководства пользователя / программное обеспечение

Аксессуары / Запчасти

Nr
Order code
Specification